Built to spec
Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.
Harrowgate Group self-performs deep foundation piling across the GTA and Ontario for developers, municipalities, industrial owners, general contractors, and geotechnical engineers. The field package is planned around design and test-pile approval, rig mobilization, platform readiness, utility clearance, production rate, obstructions, concrete supply, testing and engineer acceptance, pile trimming, excavation, and pile-cap release, with the work executed and managed by Harrowgate.
Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.
Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.
Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.
Heavy-duty steel and finishes chosen for the load, traffic, and environment on site.
Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.
Installation and site work completed in accordance with Ontario requirements.
Deep foundation piling transfers structural loads through weak near-surface soils to competent soil or rock using driven, drilled, helical, micropile, caisson, or other engineered elements. Harrowgate Group self-performs and manages enabling, excavation, concrete, pile-cap, grade-beam, and civil work across the GTA and Ontario around engineered piling systems and load-test requirements.The piling package is built from the geotechnical model, design loads, pile type, founding criterion, groundwater, obstructions, vibration limits, access, headroom, working platform, spoil handling, cut-off elevation, testing, and cap connection.
Self-performed on site to the engineered drawings, coordinated with concrete, servicing, and the surrounding work, then a clean, documented finish.
We confirm survey control, utility clearance, working-platform capacity, equipment access, overhead limits, environmental controls, pile layout, cutoff levels, and the approved installation and testing plan before production. Spoils, slurry, groundwater, casing, tremie placement, welds or mechanical sections, and adjacent movement are controlled according to the selected system and site-specific engineered procedure.
The governing document set is the 2024 Ontario Building Code, CSA A23.3, CSA A23.1 and A23.2, applicable OPSS requirements, sealed geotechnical and structural design, engineered working-platform criteria, and project load-testing requirements. Applicable OPSS requirements govern piling on provincial and municipal civil contracts where invoked. Project documents define dynamic, static, integrity, proof, or production testing frequency and acceptance.
The price responds to pile type, count, depth and capacity, access, headroom, working platform, obstructions, rock, groundwater, casing, spoil disposal, concrete or steel quantity, testing, mobilization, vibration controls, and cap work. An inadequate working platform can overturn or immobilize heavy rigs. Platform design, drainage, proofing, maintenance, and access control are treated as critical temporary works.
The controlling schedule factors are design and test-pile approval, rig mobilization, platform readiness, utility clearance, production rate, obstructions, concrete supply, testing and engineer acceptance, pile trimming, excavation, and pile-cap release. Spoils, slurry, groundwater, casing, tremie placement, welds or mechanical sections, and adjacent movement are controlled according to the selected system and site-specific engineered procedure.
Yes. Low-vibration systems, monitoring, isolated rig routes, noise windows, spoil control, and phased pile groups allow work beside operating facilities or public infrastructure when the design and logistics support it. An inadequate working platform can overturn or immobilize heavy rigs. Platform design, drainage, proofing, maintenance, and access control are treated as critical temporary works.
We compile pile layout surveys, installation logs, material records, concrete or grout tickets, reinforcement checks, depth and founding data, test results, movement monitoring, cutoff survey, engineer acceptance, and cap connection inspections. Applicable OPSS requirements govern piling on provincial and municipal civil contracts where invoked. Project documents define dynamic, static, integrity, proof, or production testing frequency and acceptance.
Provide geotechnical and structural reports, pile schedule and loads, drawings, test requirements, utility and obstruction information, access and headroom, working-platform data, groundwater conditions, monitoring limits, and milestone dates. Spoils, slurry, groundwater, casing, tremie placement, welds or mechanical sections, and adjacent movement are controlled according to the selected system and site-specific engineered procedure.
Commercial and heavy-civil construction, self-performed for developers, contractors, property managers, and municipalities.
Send drawings, a site plan, or a description of the scope. Harrowgate Group is licensed, insured, and WSIB certified.
Licensed, Insured & WSIB Certified · Self-performed and documented on every job
Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.
Harrowgate Group provides deep foundation piling, delivered and installed with quote-ready support across Toronto and surrounding Ontario communities.
Companies We've Worked With
Harrowgate Group delivers commercial and heavy-civil construction for developers, contractors, institutions, municipalities, and property groups across Ontario.