Built to spec
Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.
Harrowgate Group self-performs joint sealing across the GTA and Ontario for facility managers, municipalities, developers, general contractors, and civil engineers. The field package is planned around joint preparation rate, edge repairs, dry weather, substrate temperature, primer and sealant cure, traffic closures, access, and coordination with washing, coating, or paving, with the work executed and managed by Harrowgate.
Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.
Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.
Built to your engineered drawings, survey, and the real site conditions, not a standard package forced to fit.
Heavy-duty steel and finishes chosen for the load, traffic, and environment on site.
Send specs, drawings, or photos and get a free, no-obligation site visit and estimate with no guesswork.
Installation and site work completed in accordance with Ontario requirements.
Joint sealing installs a compatible elastomeric system in designed or repaired joints to control water, incompressibles, chemicals, and air while accommodating movement. Harrowgate Group self-performs saw cutting, removal, preparation, backing, priming, sealant placement, tooling, and traffic protection across the GTA and Ontario for concrete, masonry, pavement, and building-envelope joints.Performance depends on joint geometry and adhesion to two prepared faces.
Clean site work and a tidy finish, coordinated with your engineers, the other trades, and the surrounding site conditions, built to the engineered drawings and the applicable codes.
We survey the joint network, record widths and edge damage, identify active leaks and movement, and confirm whether failed concrete nosings or joint hardware require repair before resealing. Old material is cut and removed without damaging joint faces. Sawing, grinding, abrasive preparation, and vacuuming produce clean, dry, parallel bonding surfaces at the specified depth.
The governing document set is applicable OPSS requirements for civil joints, the 2024 Ontario Building Code, project joint schedules, approved product data, manufacturer preparation limits, and consultant adhesion-testing requirements. Width-to-depth ratio, minimum and maximum depth, primer, backer diameter, installation temperature, and cure-to-service time follow the approved system data and project specification.
The price responds to joint length and width, removal difficulty, edge repairs, substrate moisture, sealant chemistry, access, traffic control, temperature protection, primer, backer, and required cure window. Opening traffic before cure deforms or tracks the sealant. We define realistic closures, use suitable cure chemistry, and maintain protection until service criteria are met.
The controlling schedule factors are joint preparation rate, edge repairs, dry weather, substrate temperature, primer and sealant cure, traffic closures, access, and coordination with washing, coating, or paving. Old material is cut and removed without damaging joint faces. Sawing, grinding, abrasive preparation, and vacuuming produce clean, dry, parallel bonding surfaces at the specified depth.
Yes. We divide floors, facades, or pavements into short closures, maintain alternate routes, control odour and dust, and return each zone after the specified cure period. Opening traffic before cure deforms or tracks the sealant. We define realistic closures, use suitable cure chemistry, and maintain protection until service criteria are met.
We check joint dimensions, surface cleanliness, backer depth, primer use, batch and weather conditions, sealant continuity, tooling profile, adhesion test results, cure protection, and repaired edge condition. Sealant selection considers movement capability, hardness, tear resistance, fuel or chemical exposure, immersion, ultraviolet exposure, temperature, traffic, cure mechanism, and compatibility with concrete or adjacent membranes.
Provide joint plans or measured lengths, typical width and depth, substrate and exposure, photographs, existing material, leak or movement history, traffic loads, access, closure limits, and finish requirements. Old material is cut and removed without damaging joint faces. Sawing, grinding, abrasive preparation, and vacuuming produce clean, dry, parallel bonding surfaces at the specified depth.
Commercial and heavy-civil construction, self-performed for developers, contractors, property managers, and municipalities.
Send drawings, a site plan, or a description of the scope. Harrowgate Group is licensed, insured, and WSIB certified.
Licensed, Insured & WSIB Certified · Self-performed and documented on every job
Tell us what you need and we’ll get you a quote. Licensed, insured & WSIB certified · Free, no-obligation quote & on-site assessment.
Harrowgate Group provides joint sealing, delivered and installed with quote-ready support across Toronto and surrounding Ontario communities.
Companies We've Worked With
Harrowgate Group delivers commercial and heavy-civil construction for developers, contractors, institutions, municipalities, and property groups across Ontario.